Diagnostic Fault Information
WARNING: This page is about a different variant/trim than selected.
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Relay Coil Ignition | P0480, P0481, P0482 | P0480, P0481, P0482 | - | - |
| Fan Low Relay Switch B+ | 1 | 2 | - | - |
| Fan Mid 1 Relay Switch B+ | 1 | 4 | - | - |
| Fan Mid 2 Relay Switch B+ | 5 | 6 | - | - |
| Fan HI Relay Switch B+ | 5 | 8 | - | - |
| Fan Control Relay Switch | 9 | 1 | 7 | - |
| Fan Low Relay Control | P0480 | P0480 | P0480 | - |
| Fan Mid 1 Relay Control | P0481 | 4 | P0481 | - |
| Fan Mid 2 Relay Control | P0481 | 6 | P0481 | - |
| Fan HI Relay Control | P0482 | P0482 | P0482 | - |
| Fan Control Relay Control | P0481 | 1 | P0481 | - |
| Fan Low Relay Controlled Output | 1 | 2 | 3 | - |
| Fan Mid 1 Relay Controlled Output | 1 | 4 | 3 | - |
| Fan Mid 2 Relay Controlled Output | 5 | 6 | 7 | - |
| Fan HI Relay Controlled Output | 5 | 8 | 7 | - |
| Fan Control Relay Controlled Output | 9 | 10 | 7 | - |
|
||||