LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 8 (Hybrid/EV Energy Storage System) >> Diagnostic Information and Procedures >> DTC P0C77 or P1A20 >> Diagnostic Aids

Diagnostic Aids

WARNING: This page is about a different variant/trim than selected.
NOTE:

If the high voltage contactors opened while under high current load, replace BOTH high voltage contactors. The following conditions could cause the high voltage contactors to open while under high current load:

  • A collision resulting in supplemental inflatable restraint (SIR) deployment.
  • A collision that activates the high voltage circuit impact detection (HVCID) sensor.
  • A high voltage circuit impact detection sensor circuit fault that occurs while the vehicle is moving.
  • A loss of power or ground to the drive motor generator battery control module while the vehicle is moving.

The precharge time can be affected by the following:

A long or short precharge time may cause any of the following;

The drive motor generator battery control module will start a precharge wait timer after failing 2 consecutive precharge events. The contactors will not close until the precharge wait time has timed out.