Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
DTCs P0B3C, P0B41, P0B46, P0B4B, P0B50, P0B55, P0B5A, P0B5F, P0B64, P0B69, P0B6E, P0B73, P0B78, P0B7D, P0B82, P0B87, P0B8C, P0B91, P0B96
The voltage of any two consecutive batteries multiplied by 20 is 70 V greater than or less than the total pack voltage for 16 seconds.
DTC P0B9B
The voltage of battery 20 multiplied by 20 is 70 V greater than or less than the total pack voltage for 16 seconds. DTC P0B9B only requires one voltage failure because battery 20 is the last battery.