Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0AC0
One of the following conditions exists:
- The drive motor generator battery control module detects greater than 5 A on the current sensor after a successful high voltage system power down and after the contactors have opened.
- The drive motor generator battery control module detects an increase in total pack voltage greater than 10 V and the current sensor measures less than a 0.5 A increase.
- The drive motor generator battery control module detects less than 20 A on the high range sensor and the difference between the high range current measurement and the medium range current measurement is greater than 20 A for 3 seconds.
- The drive motor generator battery control module detects less than 20 A on the high range sensor and the difference between the high range current measurement and the low range current measurement is greater than 4 A for 3 seconds.
P0AC1
The drive motor generator battery control module detects that the current sensor high range is greater than +200 A and the current sensor medium range is greater than +52 A and the current sensor low range is greater than +22 A for 3 seconds.
P0AC2
The drive motor generator battery control module detects that the current sensor high range is less than -200 A and the current sensor medium range is less than -52 A and the current sensor low range is greater than -22 A for 3 seconds.
P1A07
The drive motor generator battery control module detects less than 4.8 V or greater than 5.2 V on the 5 V reference circuit.