Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P1B05 and P1B06
- The motor control module does not detect high voltage interlock circuit current flow.
- DTC P1B05 and P1B06 set within 1 second when the above condition is met.
P1AE2
- The battery energy control module detects high voltage interlock circuit source current is less than 5 mA and high voltage interlock return current is less than 5 mA.
- DTC P1AE2 sets within 1 second when the above condition is met.
P1AE3
- The battery energy control module detects high voltage interlock source current is between 5-18 mA and high voltage interlock return current is less than 5 mA.
- DTC P1AE3 sets within 1 second when the above condition is met.
P1AE4
- The battery energy control module detects high voltage interlock source current is less than 5 mA and high voltage interlock return current is greater than 35 mA.
- DTC P1AE4 sets within 1 second when the above condition is met.