LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Automatic Transmission - 2ML70 - Description And Operation) >> Description and Operation >> Automatic Transmission Hydraulic Diagrams >> Drive Range, Third Gear >> Hybrid Low, 1-2 Clutch Releases

Hybrid Low, 1-2 Clutch Releases

WARNING: This page is about a different variant/trim than selected.

Pressure Control (PC) Solenoid 3 Trim 

The PC solenoid 3 trim is de-energized (OFF) allowing PCS 3 signal fluid to exhaust from the hybrid low, 1-2 clutch regulator valve; the hybrid low, 1-2 clutch boost valve; and the shift solenoid valve - mode B.

Shift Solenoid 2 

The shift solenoid 2 is energized, allowing actuator feed limit fluid to enter the solenoid 2 signal fluid circuit. Solenoid 2 signal fluid is routed through orifice #40 to the shift solenoid valve - mode B.

Hybrid Low, 1-2 Clutch Assembly 

HL 12 clutch fluid exhausts from the hybrid low, 1-2 clutch to the shift solenoid valve - mode B allowing the hybrid low, 1-2 clutch to release.

Shift Solenoid Valve - Mode B 

Solenoid 2 signal fluid is routed to the shift solenoid valve - mode B and moves the valve against shift solenoid valve - mode B spring force to the applied position. This allows HL 12 clutch fluid pressure to exhaust through the valve into the backfill circuit. Also, HD 234 clutch/B cooling feed fluid replaces HD 234 clutch supply fluid, in order to feed the HD 234 clutch circuit and keep the hybrid direct, 2-3-4 clutch applied.

Hybrid Low, 1-2 Clutch Boost Valve 

Hybrid low, 1-2 clutch boost valve spring force moves the hybrid low, 1-2 clutch boost valve to the released position, allowing HL 12 clutch/4th clutch feedback fluid pressure to exhaust into the HL 12 clutch/4th clutch feed circuit.

Hybrid Low, 1-2 Clutch Regulator Valve 

Hybrid low, 1-2 clutch regulator valve spring force moves the hybrid low, 1-2 clutch regulator valve to the released position, allowing HL 12 clutch/4th clutch feed fluid pressure to exhaust through the valve in the backfill circuit.

Clutch Piston Exhaust Blowoff Ball Valve 

Excess fluid pressure in the backfill circuit exhausts at the clutch piston exhaust blowoff ball valve in order to maintain a constant backfill fluid pressure of 2 psi.

#5 Pressure Switch 

The applied shift solenoid valve - mode B closes off the PS5 circuit exhaust, allowing fluid pressure in the circuit to build to actuator feed limit fluid pressure. PS5 fluid opens the normally closed #5 pressure switch, signaling the TCM that the transmission is in Drive Range - Third Gear.

#1 Pressure Switch 

Actuator feed limit fluid passes through the hybrid low, 1-2 clutch regulator valve into the PS1 fluid passage. PS1 fluid opens the normally closed #1 pressure switch, signaling the TCM that the transmission is in Drive Range - Third Gear.

#3 Pressure Switch 

Actuator feed limit fluid passes through the hybrid low, 1-2 clutch regulator valve into the PS3 fluid passage. PS3 fluid opens the normally closed #3 pressure switch, signaling the TCM that the transmission is in Drive Range - Third Gear.