LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Hybrid/EV Cooling System) >> Diagnostic Information and Procedures >> DTC P0AAD-P0AAF or P0AB2-P0AB4 >> Typical Scan Tool Data

Typical Scan Tool Data

WARNING: This page is about a different variant/trim than selected.
Hybrid Batt. Inlet Air Temperature

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Range:  26°C (79°F)
Air Inlet Temperature Sensor Signal 100°C (212°F) -40°C (-40°F) -40°C (-40°F)
Air Inlet Temperature Sensor Low Reference - -40°C (-40°F) -
Hybrid Batt. Outlet Air Temperature

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Range:  26°C (79°F)
Air Outlet Temperature Sensor Signal 100°C (212°F) -40°C (-40°F) -40°C (-40°F)
Air Outlet Temperature Sensor Low Reference - -40°C (-40°F) -