LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Hybrid/EV Cooling System) >> Diagnostic Information and Procedures >> DTC P0A9C-P0A9E, P0AC6-P0AC8, P0ACB-P0ACD, P0AE9, P0AEA, or P0AEB >> Conditions for Setting the DTC

Conditions for Setting the DTC

WARNING: This page is about a different variant/trim than selected.

P0A9C, P0AC6, P0ACB, and P0AE9 

The hybrid battery temperature sensor is in normal operating range, but is 15°C (59°F) different from the other 3 sensors.

P0A9D, P0AC7, P0ACC, and P0AEA 

The hybrid battery temperature is greater than 95°C (203°F) and one other temperature sensor is less than 70°C (158°F).

P0A9E, P0AC8, P0ACD, and P0AEB 

The hybrid battery temperature is less than -40°C (-40°F).