LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Hybrid/EV Cooling System) >> Diagnostic Information and Procedures >> DTC P0A81 or P0BC1 >> Circuit/System Description

Circuit/System Description

WARNING: This page is about a different variant/trim than selected.

The drive motor generator battery is cooled by a drive motor battery vent fan motor. The battery vent fan motor and battery vent fan relay are located inside the drive motor generator battery assembly. B+ to the battery vent fan is provided from the battery vent fan relay when the drive motor generator battery control module (BECM) supplies a ground to the battery vent fan relay. A ground wire from the battery vent fan motor assembly completes the path to case ground. A 5 V circuit is provided from the battery vent fan motor assembly, to the drive motor generator battery control module. The drive motor generator battery control module uses a pulse width modulated (PWM) signal on the 5 V circuit to control the battery vent fan motor duty cycle. The drive motor generator battery control module uses 4 battery temperature sensors, one air inlet duct and one air outlet temperature sensor to control battery vent fan motor operation and speed.