LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Hybrid/EV Cooling System) >> Diagnostic Information and Procedures >> DTC P0A7E or P1ABE >> Typical Scan Tool Data

Typical Scan Tool Data

WARNING: This page is about a different variant/trim than selected.
Hybrid Batt. Mod. 1-4 Temperature

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  The ignition is ON.
Parameter Normal Value:  26°C (78.8°F)
Temperature Sensors 1-4 Signal 100°C (212°F) -40°C (-40°F) -40°C (-40°F)
Temperature Sensors 1-4 Low Reference - -40°C (-40°F) -