Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition ON, verify that the instrument panel cluster (IPC) warning indicators are illuminated.
- If the IPC warning indicators are not illuminated, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the IPC.
- Ignition OFF, disconnect the X1 harness connector at the K20 Engine Control Module.
- Ignition ON, verify the MIL is not illuminated.
- If the MIL is illuminated, test the MIL control circuit for a short to ground. If the circuit tests normal, replace the IPC.
- Connect a 3 A fused jumper wire between the MIL control circuit, terminal X1-12, and ground. The MIL should illuminate.
- If the MIL does not illuminate, test the MIL control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the IPC.
- If all circuits test normal, replace the K20 Engine Control Module.