Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 13 (Engine Controls/Fuel - Hybrid (LZ1) - DTC P0351 To DTC P3449 And Diagnostic Information And Procedures) >> Diagnostic Information and Procedures >> DTC P0496 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Ignition ON, engine OFF.
  2. Seal the EVAP system using the Purge/Seal function with a scan tool.
  3. Start the engine.
  4. Observe the FTP sensor with a scan tool. The FTP sensor parameter should be less than 1.7 V after 90 s.
    • If the FTP sensor parameter is greater than the specified range, replace the Q12 Evaporative Emission Purge Solenoid Valve.