LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2013 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (Engine Controls/Fuel - Hybrid (LZ1) - DTC P0010 To DTC P0341) >> Diagnostic Information and Procedures >> DTC P0116 >> Typical Scan Tool Data

Typical Scan Tool Data

WARNING: This page is about a different variant/trim than selected.
ECT Sensor Temperature

Circuit Normal Range Short to Ground Open Short to Voltage
ECT Sensor Signal -39 to +120°C (-38 to +248°F) 150°C (302°F) -40°C (-40°F) -40°C (-40°F)
Low Reference - - -40°C (-40°F) -40°C (-40°F)