Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0153
- The ECM detects that the HO2S 1 rich-to-lean or lean-to-rich average response time is more than 0.14 second.
- These DTCs set within 60 seconds when the above condition is met.
P0154
- The ECM detects that the HO2S 1 parameter is between 400-500 mV.
- The Throttle Position (TP) Indicated Angle parameter changes more than 5 percent.
- These DTCs set within 101 seconds when the above conditions are met.
P0160
- The ECM detects that the HO2S 2 parameter is between 400-500 mV.
- The TP Indicated Angle parameter changes more than 5 percent 5 times.
- These DTCs set within 101 seconds when the above conditions are met.
P1153
- The ECM detects that the HO2S 1 rich-to-lean counts, or the lean-to-rich counts are less than a calibrated value.
- These DTCs set within 60 seconds when the above condition is met.
P2272
- The ECM detects that the HO2S voltage oscillations are slower than a calibrated value.
- DTC P2272 sets within 4 seconds when the above condition is met continuously, or within 50 seconds when the above condition is met cumulatively.
P2273
- The ECM detects that the HO2S voltage oscillations are faster than a calibrated value.
- DTC P2273 sets within 4 seconds when the above condition is met continuously, or within 50 seconds when the above condition is met cumulatively.
P2A00 or P2A03
- The ECM detects that the Loop Status parameter is open.
- DTCs P2A00 and P2A03 set within 5 seconds when the above condition is met.
P2A01 or P2A04
- The ECM detects that the HO2S 2 did not transition below 299 mV and above 751 mV during the passive test.
- One of the following tests fail once per trip/runs until pass or fail reporting:
- Lean Intrusive Test-The ECM detects that the HO2S 2 is more than 751 mV for 8 seconds.
- Rich Intrusive Test-The ECM detects that the HO2S 2 is less than 299 mV for 8 seconds.
- DTCs P2A00 and P2A03 set within 2 minutes when the above conditions are met.
- The ECM detects that the Loop Status parameter is open by not meeting the voltage criteria to enable Close Loop fueling.
- Voltage cannot be between 250-600 mV for 10 seconds after the O2 has seen a ready to go Closed Loop command.
- DTCs P2A00 and P2A03 set within 5 minutes when the above conditions are met.