Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
IMPORTANT:
You must complete the Circuit/System Verification before proceeding with Circuit/System Testing.
- Ignition OFF, disconnect the appropriate CMP actuator solenoid harness connector at the appropriate CMP actuator solenoid.
- Connect a test lamp between the control circuit terminal B and ground.
- Engine running, command the CMP actuator solenoid from 0-20 degrees. The test lamp should turn ON and OFF when changing between commanded states.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal replace the ECM.
- If test lamp is always OFF, test the control circuit for a short to ground, an open/high resistance. If the circuit tests normal replace the ECM.
- Ignition OFF and scan tool disconnected for 90 seconds, test for less than 5 ohms between the low reference circuit terminal A and ground.
- If greater than 5 ohms, test the low reference for an open/high resistance. If the circuit tests normal replace the ECM.
- If all circuits test normal, test or replace the CMP Actuator solenoid.