LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2009 >> STS V >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transmission - 6L50/6L80 - Removal & Installation, Service, Overhaul, Troubleshooting & Diagnosis >> Repair Instructions - Off Vehicle >> Torque Converter Housing with Fluid Pump Installation

Torque Converter Housing with Fluid Pump Installation

Fig 1: View Of Torque Converter Housing With Fluid Pump (& Tightening Sequence )
GM1874823Courtesy of GENERAL MOTORS CORP.
Callout Component Name
1 NEW Fluid Pump Seal
2 Torque Converter (with Fluid Pump) Housing Assembly
CAUTION: Ensure the turbine shaft (O-ring) seal is not installed prior to installing the torque converter housing assembly. The seal may become cut or damaged during installation of the torque converter housing assembly.
3 Bolt
Tip: 
  • 6L50 Bolt M8 x 1.25 x 50 (Qty: 8)
  • 6L80 Bolt M10 x 1.5 x 50 (Qty: 9)
CAUTION: Refer to Fastener Caution .

Tighten: 

  • Tighten 6L50 bolts to 31 N.m (23 lb ft) in the sequence shown.
  • Tighten 6L80 bolts to 72 N.m (53 lb ft) in the sequence shown.

4 NEW Turbine Shaft (O-Ring) Seal