    Fig 1: View Of MAF/IAT Sensor & Engine Wiring Harness Electrical Connector
    GM1960228Courtesy of GENERAL MOTORS CORP.
  1. Remove the air cleaner outlet duct from the mass air flow (MAF)/intake air temperature (IAT) sensor. Refer to Air Cleaner Resonator Outlet Duct Replacement .
  2. Disconnect the engine wiring harness electrical connector (2) from the MAF/IAT sensor (1).
  3. Fig 2: View Of Air Cleaner Assembly & Mounting Components
    GM1707477Courtesy of GENERAL MOTORS CORP.
  4. Pull up on the front of the air cleaner assembly in order to release the retainers (2) from the air cleaner adapter.
  5. Slide the air cleaner assembly forward disengaging the locator (1) from the adapter.
  6. Remove the air cleaner assembly.
  7. If replacing the air cleaner assembly proceed to the following step otherwise proceed to step 5 in the installation procedure.
  8. Fig 3: View Of MAF/IAT Sensor Adapter & Clamp
    GM1703691Courtesy of GENERAL MOTORS CORP.
  9. Loosen the MAF/IAT sensor adapter clamp.
  10. Remove the MAF/IAT sensor and adapter.