Drive Motor Generator Battery Replacement
WARNING: This page is about a different variant/trim than selected.
| Callout | Component Name |
|---|---|
|
WARNING:
Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed. Preliminary Procedure: Disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling .The High Voltage Disabling procedure will perform the following tasks:
Failure to follow the procedures exactly as written may result in serious injury or death. |
|
| 1 | Drive Motor Battery Positive, Negative, and Ground Shield Cable Terminal Fastener Nut (Qty: 3)
CAUTION:
Refer to Fastener Caution
.
Tighten: 9 N.m (80 lb in) |
| 2 | Drive Motor Battery 300 Volt Positive and Negative Cable
WARNING:
High Voltage (HV) cables are not repairable. After disconnecting HV cables, protect and insulate ring terminal ends immediately with the EL-48569 terminal covers and UL® Listed, or equivalent, insulation tape rated at a minimum of 600 volts. Damage caused to unprotected terminal ends will result in cable replacement. Special Tools: EL-48569 Terminal Covers. See Special Tools . |
| 3 | Battery Vent Tube Tip: Remove the vent tube from the vehicle. |
| 4 | Drive Motor Generator Battery Retainer Nut (Qty: 2) Tighten: 50 N.m (37 lb ft) |
| 5 | Cooling Duct Retainer |
| 6 | Cooling Duct |
| 7 | Drive Motor Generator Battery Ground Nut Tighten: 25 N.m (18 lb ft) |
| 8 | Drive Motor Generator Battery Mounting Nut Tighten: 25 N.m (18 lb ft) |
| 9 | Drive Motor Generator Battery Ground Bolt Tighten: 25 N.m (18 lb ft) |
| 10 | Drive Motor Battery Cable Terminal Extension Cover Procedure: Disconnect the X350 harness connector from the drive motor generator battery. |
| 11 | Drive Motor Battery Cable Terminal Extension Cover Bolt (Qty: 4) Tighten: 6 N.m (53 lb in) |
| 12 | Lifting Point - Right Side |
| 13 | Lifting Points - Left Side |
| 12 | Drive Motor Battery Assembly
WARNING:
The high voltage (HV) battery must be protected when outside of the vehicle. Storage Guidelines
Unqualified Access Guidelines
Failure to follow these guidelines may result in serious injury or death. Procedure: After the battery assembly has been replaced and the re-assembly of the drive motor generator battery, enable the HV system. Refer to High Voltage Enabling . Tip: Some portable lifting devices may require raising the vehicle or the removal of the rear tire to permit access of boom into the vehicle. Special Tools: EL-48265 Battery Lifting Fixture. See Special Tools . |