Hybrid Batt. Inlet Air Temperature

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Range:  26°C (79°F)
Air Inlet Temperature Sensor Signal 100°C (212°F) -40°C (-40°F) -40°C (-40°F)
Air Inlet Temperature Sensor Low Reference - -40°C (-40°F) -
Hybrid Batt. Inlet Air Temperature Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Range:  0.5 to 4.3 Volts
Air Inlet Temperature Sensor Signal 0 Volts 4.75 Volts 5 Volts
Air Inlet Temperature Sensor Low Reference - 4.75 Volts -
Hybrid Batt. Outlet Air Temperature

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Range:  26°C (79°F)
Air Outlet Temperature Sensor Signal 100°C (212°F) -40°C (-40°F) -40°C (-40°F)
Air Outlet Temperature Sensor Low Reference - -40°C (-40°F) -
Hybrid Batt. Outlet Air Temp Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON
Parameter Normal Range:  0.5 to 4.3 Volts
Air Outlet Temperature Sensor Signal 0 Volts 4.75 Volts 5 Volts
Air Outlet Temperature Sensor Low Reference - 4.75 Volts -