Trans. Fluid Temp.

Circuit Short to Ground Open/High Resistance Short to Voltage
Operating Conditions:  Engine running in Park, normal operating temperature
Parameter Normal Range:  -39 to +149°C (-38 to +300°F)
TFT Signal Greater than 149°C (300°F) Less than -39°C (-38°F) Less than -39°C (-38°F)*
Low Reference - Less than -39°C (-38°F) Less than -39°C (-38°F)*
* Internal TFT sensor damage may result if shorted to B+