Home >> Cadillac >> 2009 >> Escalade Base, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 10 (Engine Control System & Fuel - Hybrid (Hp2) 6.0L (LFA) - Troubleshooting & Diagnosis) >> Evaporative Emission System Diagnosis >> Temperature Variation Instructions >> The Concern

The Concern

WARNING: This page is about a different variant/trim than selected.

Ideal circumstances for conducting the EVAP Flowmeter Test require equal temperatures between the nitrogen gas and the vehicle EVAP system. Significant differences in temperature between them can result in a flow or pressure change during testing, causing misleading results. Typically, the Evaporative Emissions System Tester is stored indoors, approximately 21°C (70°F). Vehicles brought in for diagnosis may have an EVAP system at significantly different temperatures -40 to +43°C (-40 to +110°F).