Mode Actuator Replacement
Mode Actuator Replacement
Removal Procedure
1. Remove the instrument panel (I/P) carrier. Refer to Instrument Panel Carrier Replacement (Service and Repair) .
2. Disconnect the mode actuator electrical connector.
3. Remove the mode actuator screws (3).
4. Remove the mode actuator.
Installation Procedure
1. Install the mode actuator.
Notice: Refer to Fastener Notice .
2. Install the mode actuator screws (2).
Tighten the screws to 1 N.m (9 lb in).
3. Connect the electrical connector to the actuator.
4. Install the I/P carrier. Refer to Instrument Panel Carrier Replacement (Service and Repair) .