Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the receiver module.
- Test for less than 10 ohms between the ground circuit terminals 9 and 16 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Verify that a test lamp illuminates between the B+ circuit terminals 1 and 18 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Connect the harness connector at the receiver module.
- Disconnect the harness connector at the master motor.
- Test for less than 10 ohms between the ground circuit terminal 2 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Verify that a test lamp illuminates between the B+ circuit terminal 4 and ground.
- If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
- Connect a test lamp between the wake up signal circuit terminal 5 and ground.
- Press the key fob open button. The test lamp should illuminate.
- If the test lamp does not illuminate, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the receiver module.
- Connect a test lamp between B+ and the open signal circuit terminal 11.
- Press the key fob open button. The test lamp should illuminate.
- If the test lamp does not illuminate, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the receiver module.
- Connect a test lamp between B+ and the close signal circuit terminal 12.
- Press the key fob close button. The test lamp should illuminate.
- If the test lamp does not illuminate, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the receiver module.
- Disconnect the harness connector at the slave motor.
- Test for less than 10 ohms between the ground circuit terminal 9 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Verify that a test lamp illuminates between the B+ circuit terminal 5 and ground.
- If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.
- Test for less than 2 ohms between the master motor X Bus circuit terminal 6 and slave motor X Bus circuit terminal 1.
- If all circuits test normal replace the master and slave motors.