Circuit/System Testing
- Ignition ON, scan tool installed and open the door with the inoperative door lock status indicator. Verify that the Lock Switch Indicator Command parameter does not cycle between On/Off.
- If not, test the inoperative door lock status indicator supply voltage circuit and the ground circuit for a short to voltage, a short to ground and an open/high resistance. If the circuits test normal, replace the door lock status indicator.