Circuit/System Testing
- Ignition OFF, disconnect both the liftgate and liftglass ajar switches.
- Ignition OFF, test for less than 1 ohm of resistance between the low reference circuit and ground.
- If greater than 1 ohm, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool Liftgate Ajar Switch parameter is Inactive.
- If not Inactive, test the signal circuit for a short to ground. If the circuit tests normal, replace the BCM.
- Ignition ON, check to see that the rear access open message is not displayed.
- If the message is displayed in the DIC, replace the IPC.
- Ignition ON, install a 3-amp fused jumper wire between the signal circuit and ground. Verify the scan tool Liftgate Ajar Switch parameter is Active.
- If not Active, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal replace the BCM.
- Ignition ON, check to see that the rear access open message is displayed.
- If the message is not displayed in the DIC, replace the IPC.
- If all circuits test normal, test or replace the liftgate ajar switch or the liftglass ajar switch.