HVAC Control Module Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C Clutch-actual A/C Compressor Data On/Off On
A/C Clutch-Desired A/C Compressor Data Yes/No Yes
AC Pressure A/C Compressor Data kPa/psi Varies
Commanded Blower HVAC System Data % Varies
Coolant Temperature HVAC System Data °C/°F Varies
Driver Temp. Dr. Actual HVAC Door Positions Counts/Volts Varies
Driver Temp. Dr. Commanded HVAC Door Positions Counts/Volts Varies
Driver Solar Sensor Open/Short Data Counts/Volts Varies
Driver Sunload HVAC System Data w/m2 Varies
Evaporator Temp HVAC System Data °C/°F Varies
Evaporator Temp A/C Compressor Data °C/°F Varies
Evaporator Temp Open/Short Data Counts/Volts Varies
Htr./Def./A/C Dr. Actual HVAC Door Positions Counts/Volts Varies
Htr./Def./A/C Dr. Commanded HVAC Door Positions Counts/Volts Varies
Inside Air Temp HVAC System Data °C/°F Varies
Inside Air Temp Open/Short Data Counts/Volts Varies
Low Coolant Status HVAC System Data OK/Low OK
Low Coolant Switch HVAC System Data Open/Closed Closed
Outside Air Temp HVAC System Data °C/°F Varies
Outside Air Temp Open/Short Data Counts/Volts Varies
Passenger Solar Sensor Open/Short Data Counts/Volts Varies
Passenger Sunload HVAC System Data w/m2 Varies
Passenger Temp Dr. Actual HVAC Door Positions Counts/Volts Varies
Passenger Temp Dr. Commanded HVAC Door Positions Counts/Volts Varies
Pressure Sensor A/C Compressor Data OK/Failed OK
Vehicle Speed HVAC System Data Km/h/mph Varies
ECM Scan Tool Data List

Scan Tool Parameter Data List Units Displayed Typical Data Value
Operating Conditions: Engine idling, A/C ON, ambient air temperature between 22-27°C (70-80°F)
A/C High Side Pressure Engine Data 2 kPa/Psi 629-845 kPa (85-120 psi)
A/C High Side Pressure Engine Data 2 Volts Varies
A/C Relay Command Engine Data 2 On/Off Varies
A/C Request Signal Engine Data 2 Yes/No Varies
ECT Sensor Engine Data 2 °C/°F 92°C (197°F)
ECT Sensor Engine Data 2 Volts 1.10-1.45 Volts