Conditions for Running the DTC
WARNING: This page is about a different variant/trim than selected.
The engine speed is between 500-6,500 RPM for at least 5 seconds.
P0815 or P0816
- No DTC P0826.
- No DTCs P1815 or P1826.
- The time since the last gear selector range change is greater than 6 seconds.
P0826
- Ignition voltage is 8.6-19.0 volts.
- Engine speed is 500-6500 RPM for at least 5 seconds.
P1876
- No DTC U0100.
- No DTCs P0815, P0816, or P0826.
- No DTCs P1825 or P1915.