Circuit/System Testing: Notes
WARNING: This page is about a different variant/trim than selected.
P0815
- Select the Driver Shift Request parameter.
- Disconnect the Automatic Transmission (AT) shift program switch connector.
- If the parameter status changes from Upshift to Invalid, replace the AT shift program switch.
- If the parameter status does not change, replace the control solenoid (w/body and TCM) valve assembly.
P0816
- Select the Driver Shift Request parameter.
- Disconnect the Automatic Transmission (AT) shift program switch connector.
- If the parameter status changes from Downshift to Invalid, replace the AT shift program switch.
- If the parameter status does not change, replace the control solenoid (w/body and TCM) valve assembly.
P0826
- Inspect the fuse in the ignition 3 voltage circuit for an open.
- If the fuse is Open, test the ignition 3 and the Tap/Up and Tap/down circuit for a short to ground.
- If the fuse is OK, test the ignition 3 and the Tap/Up and Tap/down signal circuit for an Open or Short to Voltage.
- Test the AT/DSC shift program switch for correct resistance value, 8.11-8.39 ohms.
- If the resistance is not within specifications, replace the switch assembly.
- If the resistance is within specifications, replace the control solenoid (w/body and TCM) valve assembly.