LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2006 >> STS Base, 3.6 7, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Engine Control System - 4.6L (LH2) - Introduction (2 Of 2)) >> Repair Instructions >> Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Exhaust >> Camshaft Position Actuator Solenoid Alignment Procedure

Camshaft Position Actuator Solenoid Alignment Procedure

WARNING: This page is about a different variant/trim than selected.
    Fig 1: View Of Camshaft Position Actuator Magnet & Bolts
    GM1254509Courtesy of GENERAL MOTORS CORP.
  1. Make an alignment pin from drill rod 15/64 inch diameter and at least 50 mm (1.97 in) long.
  2. Verify that the alignment pin will pass through the CMP actuator solenoid alignment hole.
  3. Verify that the alignment pin will fit into the alignment hole in the CMP actuator oil control valve.
  4. Apply a 2 mm (0.079 in) bead of RTV GM P/N 12378521 (Canadian P/N 88901148) around the flange of the CMP actuator solenoid.
  5. Install the CMP actuator solenoid over the oil control valve.
  6. Install the alignment pin through the solenoid alignment hole and into the oil control valve alignment hole.
  7. NOTE: Refer to Fastener Notice .
  8. With the alignment pin in place, install the CMP actuator solenoid bolts.

    Tighten:  Tighten the CMP actuator solenoid bolts to 8 N.m (71 lb in).

  9. Remove the alignment pin.
  10. Install a NEW CMP actuator solenoid plug.
  11. Connect the electrical connector to the actuator solenoid.
  12. Install the fuel injector sight shield. Refer to Fuel Injector Sight Shield Replacement .