LEMON Manuals: Even more car manuals for everyone
Home >> Cadillac >> 2006 >> STS Base, 3.6 7, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 15 (Engine Control System - 4.6L (LH2) - DTC P0690 To P2135) >> DTC P1138 or P1158 >> Circuit Description

Circuit Description

WARNING: This page is about a different variant/trim than selected.

The heated oxygen sensor (HO2S) produces a voltage that varies between 100-900 mV under normal operating conditions. The engine control module (ECM) produces a bias voltage on the HO2S signal circuit of 420-480 mV. The reference ground for the sensor is provided through the ECM. The ECM monitors the signal voltage to determine if the exhaust is lean or rich. The oxygen sensor voltage is high when the exhaust is rich, and low when the exhaust is lean. The ECM constantly monitors the HO2S signal during the Closed Loop operation. If the ECM detects an HO2S voltage that stays above a specified value during a fuel cutoff condition, DTC P1138 will set for bank 1 sensor 2, or DTC P1158 will set for bank 2 sensor 2.