Action Taken When the DTC Sets
WARNING: This page is about a different variant/trim than selected.
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
- The CMP actuator is commanded to the home or parked position.
- The ignition system defaults to a failed CMP sensor limp home mode.