Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0131
- The control module detects that the HO2S 1 Voltage parameter is less than 25 mV.
- DTC P0131 sets within 100 seconds during the lean test when the above condition is met.
P0132
- The control module detects that the HO2S 1 parameter is more than 950 mV.
- DTC P0132 sets within 15 seconds during the rich test when the above condition is met.
P0137 or P0157 Lean Test
- The control module detects that the HO2S 2 voltage parameter is less than 75 mV.
- These DTCs set within 100 seconds during the lean test when the above condition is met.
P0138 or P0158 Rich Test
- The control module detects that the HO2S 2 voltage parameter is more than 950 mV.
- These DTCs set within 100 seconds during the rich test when the above condition is met.
P0151
- The control module detects that the HO2S Bank 2 Sensor 1 Voltage parameter is less than 100 mV.
- DTC P0151 sets within 3 seconds when the above condition is met.
P0152
- The control module detects that the HO2S Bank 2 Sensor 1 Voltage parameter is more than 950 mV.
- DTC P0151 sets within 3 seconds when the above condition is met.
P2A00 or P2A03
- The control module detects that the Loop Status parameter is open.
- These DTCs set within 5 seconds when the above condition is met.
P2A01 or P2A04
- The control module detects that the HO2S 2 did not transition below 299 mV and above 751 mV during the passive test.
- One of the following tests fail once per trip/runs until pass or fail reporting:
- Lean Intrusive Test-The control module detects that the HO2S 2 is more than 751 mV for 8 seconds.
- Rich Intrusive Test-The control module detects that the HO2S 2 is less than 299 mV for 8 seconds.
- These DTCs set sets within 2 minutes when the above conditions are met.
- The control module detects that the Loop Status parameter is open by not meeting the voltage criteria to enable close loop fueling.
Voltage cannot be between 250-600 mV for 10 seconds after the O2 has seen a ready to go closed loop command.
- These DTCs set within 5 seconds when the above condition is met.