Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
TP Sensor 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The ignition is ON, with the engine OFF. Normal TP 1 Parameter: 4.20-0.5 V |
|||
| TP Sensor 1 and 2 5-Volt Reference | 0.04 V | 0.00 V | 4.98 V |
| TP Sensor 1 Signal | 0.00 V | 0.00 V | 4.98 V |
| TP Sensor 1 and 2 Low Reference | - | 4.98 V | - |
TP Sensor 2
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
The ignition is ON, with the engine OFF. Normal TP 2 Parameter: 0.7-4.5 V |
|||
| TP Sensor 1 and 2 5-Volt Reference | 0.04 V | 0 V | 3.63 V |
| TP Sensor 2 Signal | 0.00 V | 4.98 V | 4.98 V |
| TP Sensor 1 and 2 Low Reference | - | 4.98 V | - |