Component Testing
WARNING: This page is about a different variant/trim than selected.
Measure the CMP actuator solenoid for the following specified resistance for the given temperature.
- 3.25-3.66 ohms at 40°C (40°F)
- 4.0-4.5 ohms at 20°C (68°F)
- 4.0-4.52 ohms at 25°C (77°F)
- 5.6-6.4 ohms at 125°C (257°F)
- If the resistance is not at the specified value for the given temperature replace the affected CMP actuator solenoid.