Home >> Cadillac >> 2006 >> Escalade AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 783 (Engine Control System - 8.1L - Introduction (2 Of 2)) >> Repair Instructions >> Heated Oxygen Sensor (HO2S) Replacement Bank 2 Sensor 1 >> Removal Procedure

Removal Procedure

WARNING: This page is about a different car, the 2006 GMC Yukon XL, 2006 Chevrolet Suburban, and 2006 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Refer to Heated Oxygen and Oxygen Sensor Notice in Cautions and Notices.
    Fig 1: View Of O2 Sensor, Connector, Harness And Retainers
    GM664781Courtesy of GENERAL MOTORS CORP.
  1. Raise and suitably support the vehicle. Refer to Lifting and Jacking the Vehicle in General Information.
  2. Disconnect the connector position assurance (CPA) retainer.
    NOTE: Refer to HEATED OXYGEN AND OXYGEN SENSOR NOTICE in Cautions and Notices.
  3. Disconnect the HO2S sensor electrical connector.
  4. Fig 2: Locating HO2S - Upstream
    GM710383Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to EXCESSIVE FORCE AND OXYGEN SENSOR NOTICE in Cautions and Notices.
  5. Remove the HO2S (3).