Night Vision Display Height Adjustment Inoperative
Night Vision Display Height Adjustment Inoperative
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: Night Vision Schematics | ||||
| 1 | Did you review the Night Vision Description and Operation and perform the necessary inspections? | - | Go to Step 2 | Go to Symptoms - Instrument Panel, Gages and Console |
| 2 |
|
- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
0 V | Go to Step 4 | Go to Step 7 |
| 4 | With the DMM, measure the voltage from the night vision image up signal circuit to a good ground. Does the voltage measure at or near the specified value? |
0 V | Go to Step 5 | Go to Step 8 |
| 5 |
|
12 V | Go to Step 6 | Go to Step 9 |
| 6 |
|
12 V | Go to Step 11 | Go to Step 10 |
| 7 | Test the night vision image down signal circuit for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 12 |
| 8 | Test the night vision image up signal circuit for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 12 |
| 9 | Test the night vision image down signal circuit for an open or for a short to ground. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 12 |
| 10 | Test the night vision image up signal circuit for an open or for a short to ground. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 12 |
| 11 | Inspect for poor connections at the harness connector of the HUD. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 13 |
| 12 | Inspect for poor connections at the harness connector of the HUD switch. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
- | Go to Step 15 | Go to Step 14 |
| 13 | Replace HUD. Refer to Control Module References
in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? |
- | Go to Step 15 | - |
| 14 | Replace the HUD switch. Refer to Head Up Display Switch Replacement . Did you complete the replacement? |
- | Go to Step 15 | - |
| 15 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 2 |