Circuit Description
WARNING: This page is about a different variant/trim than selected.
The control module monitors the fuel tank pressure (FTP) sensor signal in order to detect vacuum decay and excess vacuum during the evaporative emission (EVAP) diagnostic test. The control module supplies a 5-volt reference and a low reference circuit to the FTP sensor. If the control module detects the FTP sensor signal voltage below a calibrated value, this DTC will set.
The following table illustrates the relationship between FTP sensor signal voltage and the EVAP system pressure/vacuum.
DTC P0452
| FTP Sensor Signal Voltage | Fuel Tank Pressure |
|---|---|
| High, Approximately 1.5 Volts or More | Negative Pressure/Vacuum |
| Low, Approximately 1.5 Volts or Less | Positive Pressure |