Installation Procedure
WARNING: This page is about a different variant/trim than selected.
- Install NEW fluid passage sleeves if previously removed.
- Install the control valve body accumulator assembly (1) and manual shaft detent spring (2) to the transmission.
- Install the manual shaft detent spring bolts (3) and hand tighten.
- Confirm that the manual shift shaft detent lever locating pin (2) is properly engaged with the manual valve link (1).
- Confirm that the detent spring roller (4) is properly engaged with the manual shift shaft switch (3).
- Install the control valve body accumulator assembly to the transmission case bolts (1-3) and hand tighten.
- Tighten the control valve body assembly bolts in sequence.
Tighten: Tighten the bolts to 11 N.m (97 lb in).
- Install a 0.8 mm spacer (2) between the manual shaft detent lever (1) and the manual shaft detent spring (3).
- Tighten the detent spring bolts.
Tighten: Tighten the bolts to 11 N.m (97 lb in).
- Remove the spacer (2).
- Connect the internal electrical wiring harness connectors to all internal electrical components (1-8).
- Install the transmission fluid pan and filter. Refer to Automatic Transmission Fluid/Filter Replacement .
Fig 3: Confirming Manual Shift Shaft Detent Lever Locating Pin Is Properly Engaged With Manual Valve Link
IMPORTANT:
If the bolts are tightened at random, valve bores may become distorted and inhibit proper valve operation.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.