Dieseling, Run-On
WARNING: This page is about a different variant/trim than selected.
Dieseling, Run-On
| Inspections |
Action |
| DEFINITION: The engine continues to run after the key is turned OFF, but runs very rough. If the engine runs smooth, inspect the ignition switch and the ignition switch adjustment. |
| Preliminary |
- Refer to Important Preliminary Checks Before Starting in Symptoms - Engine Controls .
- Search for bulletins.
- Verify that the engine control module (ECM) and ECM bracket fasteners are at the correct torque.
- Inspect the engine control system grounds for being clean, tight, and in the correct locations. Refer to Power and Grounding Component Views
in Wiring Systems and Engine Controls Schematics
. Ensure the resistance between the ECM housing and the battery negative cable is less than 0.5 ohms.
|
| Fuel System |
Test the fuel system for the following conditions:
|