Retained Accessory Power (RAP) On After Timeout
Retained Accessory Power (RAP) On After Timeout
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: Retained Accessory Power (RAP) Schematics | |||
| 1 | Did you perform the Diagnostic System Check - Retained Accessory Power? | Go to Step 2 | Go to Diagnostic System Check - Retained Accessory Power |
| 2 |
|
Go to Step 3 | Go to Step 9 |
| 3 | Disconnect the RAP relay. Do the RAP functions still operate? |
Go to Step 4 | Go to Step 5 |
| 4 | Repair the short to B+ in the RAP relay output circuits. Refer to WIRING REPAIRS
. Have you completed the repair? |
Go to Step 9 | - |
| 5 | Test for continuity between the normally open (NO) RAP relay switched contacts. Refer to CIRCUIT TESTING
. Did you find and correct the condition? |
Go to Step 9 | Go to Step 6 |
| 6 | Test the control circuit of the RAP relay for a short to ground. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
Go to Step 8 | Go to Step 7 |
| 7 | Inspect for poor connections at the harness connector of the BCM. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
Go to Step 9 | Go to Step 8 |
| 8 | Replace the BCM. Refer to BODY CONTROL MODULE REPLACEMENT
. Is the repair complete? |
Go to Step 9 | - |
| 9 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |