Test Description
The numbers below refer to the step numbers on the diagnostic table.
- 4. This step simulates an open MPA switch.
- 5. This step simulates a closed MPA switch.
- 6. This step tests the MPA switch by closing the switch manually.
- 7. This step tests the MPA switch by ensuring the switch plunger is in the open position.