DTC U1088: Description
Every 5 seconds while ignition switch is in RUN position, control modules that communicate on class 2 data bus transmit a performance condition signal to indicate system is operating properly. Signal is then transmitted to IPC. DTC U1088 will set when IPC does not receive signal from SDM after 3 consecutive monitoring cycles. DTC U1088 will clear when SDM transmits signal to IPC.