Generator L-Terminal Open Circuit
- Connect scan tool. Turn ignition on. Using scan tool, select IPC, DATA LIST, INPUTS, and ALT L TERMINAL. If scan tool does not display on, go to next step. If scan tool displays on, replace IPC.
- Turn ignition off. Disconnect IPC connector C1. Disconnect generator. Measure resistance in Red wire between IPC connector C1 terminal A9 and generator terminal "L". If resistance is greater than 5 ohms, go to next step. If resistance is less than 5 ohms, repair open circuit in Red wire.