Lamp On With Ignition On
Disconnect Green wire to sending unit at connector (in front of intake manifold on Seville; near A/C compressor on all others). If lamp goes off, replace sending unit. If lamp remains on, lower steering column and disconnect ignition switch connector. If lamp goes out, replace ignition switch. If lamp remains on, perform continuity checks for ground as described under "Lamp Off During Cranking".