LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2019 >> Regal TourX Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 154 (Automatic Transmission - 9T50 (M3D) And 9T60 (M3T) - Repair Instructions - Off Vehicle) >> Repair Instructions - Off Vehicle >> Control Valve Body Assembly Installation >> Control Valve Solenoid Body Wiring Harness Installation

Control Valve Solenoid Body Wiring Harness Installation

WARNING: This page is about a different car, the 2020 Buick Regal and 2019 Buick Regal. However, it is still accessible from the selected car via links, so may be relevant.
GM4420546Courtesy of GENERAL MOTORS COMPANY
Control Valve Solenoid Body Wiring Harness Installation

Callout Component Name
1 Automatic Transmission Fluid Temperature Sensor Seal
Procedure 
Install a NEW seal. Do NOT reuse the old seal.
2 Automatic Transmission Wiring Harness
Procedure 
Ensure you connect all the connectors to the valve body.
Tighten 
8 N.m (71 lb in)
NOTE:

The bolts are captured with harness.

3 Control Valve Solenoid Body Bolt
Tighten 
9 N.m (80 lb in)
4 Control Valve Body Bolt [3x]
Procedure 
Hand tighten and follow torque sequence below.