LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2019 >> Regal TourX Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 139 (Engine Controls And Fuel - 3.6L (LGX) - Diagnostic Information And Procedures (P0449-P3436) And Symptoms) >> Diagnostic Information and Procedures >> DTC P0685-P0687, P0689, P0690, P1682, P16A7, P16AF, or P16B3 >> Component Testing

Component Testing

WARNING: This page is about a different car, the 2020 Buick Regal and 2019 Buick Regal. However, it is still accessible from the selected car via links, so may be relevant.

Relay Test

  1. Ignition/Vehicle - Off
  2. Remove the component: KR75 Engine Controls Ignition Relay
  3. Test for 70 to 110 ohms between the test points: Component terminal 85 & 86
    • If not between 70 and 110 ohms 

      Replace the component: KR75 Engine Controls Ignition Relay

    • Go to next step: If between 70 and 110 ohms 
  4. Test for infinite resistance between the test points:
    • Component terminal 30 & 85
    • Component terminal 30 & 86
    • Component terminal 30 & 87
    • Component terminal 85 & 87
    • If less than infinite resistance 

      Replace the component: KR75 Engine Controls Ignition Relay

    • Go to next step: If infinite resistance 
  5. Connect a 3 A fused jumper wire between the test points: Component terminal 86 & B+

    Connect a jumper wire between the test points: Component terminal 85 & Ground

  6. Test for less than 2 ohms between the test points: Component terminal 30 & 87
    • If 2 ohms or greater 

      Replace the component: KR75 Engine Controls Ignition Relay

    • Go to next step: If less than 2 ohms 
  7. All OK.