Circuit/System Description
The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 V depending on outside lighting conditions. The body control module (BCM) provides a 5 V reference signal to the ambient light sensor and the HVAC control module provides a low reference ground. The BCM monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lamps or automatic lamp control when the headlamp switch is in the AUTO position. In daylight conditions the BCM will command the daytime running lamps ON. During low light conditions the BCM will command the low beam headlamps ON. Any function or condition that turns on the headlamps will cancel daytime running lamps operation. With the vehicle in park, the BCM commands the park lamps on which utilizes the same lamps as the daytime running lamps. Once the vehicle is in gear, the BCM then commands the daytime running lamps on with a separate circuit from the park lamps.