Static Test

  1. Ignition OFF, disconnect the harness connector at the B16 Backup Lamp Switch. Reversing gear engaged, test for less than 5 Ω at the B16 Backup Lamp Switch terminal 1 and terminal 2.
    • If greater than the specified value replace the B16 Backup Lamp Switch.
  2. Reversing gear disengaged, test for infinite resistance at the B16 Backup Lamp Switch terminal 1 and terminal 2.
    • If less than the specified value replace the B16 Backup Lamp Switch.