M37 Mode Door Actuator
| Connector Part Information Harness Type: HVAC OEM Connector: Not Available Service Connector: Service by Harness - See Part Catalog Description: -Way |
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | Not required | No Tool Required | No Tool Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.35 | YE/BN | 2273 | Mode Door Control | I | - |
| 2 | 0.35 | BK/YE | 1791 | Air Temperature Door Control Low Reference | I | - |
| 3 | 0.35 | GY/RD | 598 | 5V Reference | I | - |
| 4 | 0.35 | WH/GN | 2275 | Mode 1 Valve Position Sensor Signal | I | - |
| 6 | 0.35 | WH | 119 | Mode Door Control | I | - |