LEMON Manuals: Even more car manuals for everyone
Home >> Buick >> 2015 >> Verano Premium, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (Engine Controls And Fuel - 2.4L (Lea) - Dc P0010 To DTC P0328) >> Diagnostic Information and Procedures >> DTC P0011 or P0014: Intake/Exhaust Camshaft Position System Performance >> Component Testing

Component Testing

WARNING: This page is about a different variant/trim than selected.
  1. Ignition Off, disconnect the harness connector at the Q6 Camshaft Position Actuator Solenoid Valve.
  2. Test for 8-13 Ω between the control terminal 2 and the low reference circuit terminal 1.
    • If not between 8-13 Ω 

      Replace the Q6 Camshaft Position Actuator Solenoid Valve.

    • If between 8-13 Ω 
  3. Test for infinite resistance between each terminal and the Q6 Camshaft Position Actuator Solenoid Valve housing.
    • If not infinite resistance 

      Replace the Q6 Camshaft Position Actuator Solenoid Valve.

    • If infinite resistance 
  4. All OK